Frame size 90
Housing material Casting iron
Install model According to the standard
Type of feet Removable feet
(Standard) Fixed feet
(Optional)
Net weight 23.2 kg
Insulation class F H (Standard) (Optional)
Protection degree IP 55IP 56 (Standard)(Optional)
Thermal protection WithoutCustomizable(Standard)(Optional)
Rotation direction ClockwiseCounter clockwise(Standard)(Optional)
Service duty S1
Vibration level A
Balance Half-key balanced
Cable glands 1 - M20× 1.5
Cooling IC 411
Painting color RAL 7024Customizable(Standard)(Optional)
Regulations IEC / DIN / ISO / VDE / EN
Standard IEC 60034
Ambient temperature From -20°C to +40°C
Maximum altitute 1000 m above sea level
 
Output 1.5 kW
Frequency 50Hz
Voltage (±5%) 230V Δ @ 50Hz
400V Y @ 50Hz
276V Δ @ 60Hz
480V Y @ 60Hz
Rotation speed 1430 RPM @ 50Hz
1716RPM @ 60Hz
Rated current 6.12 A (In) @ Δ 50Hz
3.53A (In) @ Y 50Hz
Starting current 6.5 ×In
Rated torque 10.017482517 Nm (Mn)
Starting torque 2.5 ×Mn
Breakdown torque 2.6 ×Mn
Efficiency

IE2

82.8
83.4
80.4
@ 100% load
@ 75% load
@ 50% load
Power factor cosφ 0.74 @ 100% load
Bearings brand C&U Customizable(Standard)(Optional)
Bearings type 6205 2RS C3
6205 2RS C3
(DE)
(NDE)
Grease type
Moment of inertia 0.00411 Kg*m²
Noise level 61 dB(A)
Drawings Test reports Print